It connects the battery banks (starting + services) when alternator/battery charger are working and it disconnects the banks when the charging system stops.Supports high current loads (e.g., powerful inverters).Ability to connect battery banks in an emergency, with a simple switch control.Very low consumption in ON/OFF due to the bistable system.Meets ISO 8846/SAEJ1171.Deutsch 6-pin DTM male connector.
Specifications
| Property | Value |
|---|
| V | 12 |
| Control current | 40 mA*/6 A** |
| Relay contact position - closes (30 sec) with voltage | 13.5 V |
| Relay contact position - closes (90 sec) with voltage | 13.1 V |
| Relay contact position - opens (10 sec) with voltage | 12.3 V |
| Relay contact position - opens (30 sec) with voltage | 12.7 V |
| Relay contact position - opens circuit | 16.5 V*** |